JACO

Hong Kong WSD General Acceptance

Find the right fitting. Verify it at a glance.

Search Hong Kong WSD General Acceptance records by GA number, brand, complete model or product type, then verify the image, size, approval period and latest status.

Sourced directly from the official WSD GA directory and refreshed continuously

02 / RESULTS

Search results

18,597 matching recordsEach row represents an exact model/size; one GA letter may cover multiple product rows.Data retrieved: 31 Oct 2026, 01:41

RENE

C511X-I

Wall mounted sensor tap
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180657
ExpiredGA*
WSD #1010985
Origin
Chinese Mainland
Approval date
4 Oct 2018
Expiry date
12 Aug 2023
Quality-assurance evidence
Quality management system

American Standard

WF-0412.701.50

Wall mounted single lever shower mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180656
Expired
WSD #1010984
Origin
Chinese Mainland
Approval date
4 Oct 2018
Expiry date
13 Jun 2023
Quality-assurance evidence
Quality management system

American Standard

CF-0412.701.50

Wall mounted single lever shower mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180656
Expired
WSD #1010983
Origin
Chinese Mainland
Approval date
4 Oct 2018
Expiry date
13 Jun 2023
Quality-assurance evidence
Quality management system

Grohe

25168002

3-hole bath mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180655
Expired
WSD #1010982
Origin
Chinese Mainland
Approval date
3 Oct 2018
Expiry date
2 Jul 2023
Quality-assurance evidence
Not submitted

Grohe

25170002

4-hole bath mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180654
Expired
WSD #1010981
Origin
Chinese Mainland
Approval date
3 Oct 2018
Expiry date
2 Jul 2023
Quality-assurance evidence
Not submitted

THG

G00-A00-5300AE

Thermostatic mixing valve
Size
3/4 inch
Water-supply system
Fresh Water
GA numberC20180653
Expired
WSD #1010980
Origin
France
Approval date
3 Oct 2018
Expiry date
3 Jun 2023
Quality-assurance evidence
Not submitted

Axor

10974 + 15974180

Concealed shut-off valve
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180652
Expired
WSD #1010979
Origin
Germany
Approval date
3 Oct 2018
Expiry date
11 Jul 2023
Quality-assurance evidence
Quality management system

Cheung Hing

SSB150A

Stainless steel float operated valve
Size
150mm
Water-supply system
Fresh Water, Flushing Water, Fire Services
GA numberC20180650
Expired
WSD #1010978
Origin
Chinese Mainland
Approval date
3 Oct 2018
Expiry date
28 Aug 2023
Quality-assurance evidence
Not submitted

Cheung Hing

SSB40A

Stainless steel float operated valve
Size
40mm
Water-supply system
Fresh Water, Flushing Water, Fire Services
GA numberC20180650
Expired
WSD #1010977
Origin
Chinese Mainland
Approval date
3 Oct 2018
Expiry date
28 Aug 2023
Quality-assurance evidence
Not submitted

INAX

AMV-90K

Electronic sensor basin mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180649
Expired
WSD #1010975
Origin
Vietnam
Approval date
2 Oct 2018
Expiry date
28 Aug 2022
Quality-assurance evidence
Quality management system

INAX

LFV-P02B

Deck mounted self closing tap
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180648
ExpiredWELS
WSD #1010974
Origin
Vietnam
Approval date
2 Oct 2018
Expiry date
29 May 2023
Quality-assurance evidence
Quality management system
Water-efficiency label
TN 18-0070 · grade 1 · nominal flow 1.6

American Standard

WF-0902.10X.50

Single lever vessel mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20180647
Expired
WSD #1010973
Origin
Chinese Mainland
Approval date
2 Oct 2018
Expiry date
24 May 2023
Quality-assurance evidence
Not submitted

A quick pre-procurement check

Understand a WSD GA record in three steps

Confirm the product identity first, then its approval scope. A matching brand or appearance alone is not enough.
  1. 01

    Match the GA number and model

    Check the GA number, brand and complete model against the product. Related models in the same range are not automatically covered.

  2. 02

    Check size and intended use

    One GA letter can cover several sizes or configurations. Match the water-supply system, size and fitting classification to the work.

  3. 03

    Review expiry and surveillance

    Confirm that approval is not expired, suspended or removed, and re-open the official record before a formal submission or inspection.

What is General Acceptance?

A GA record is a key reference when checking plumbing-product compliance

Pipes and fittings used in Hong Kong inside-service and fire-service installations must meet Water Authority requirements. Accepted products receive a General Acceptance record; its official model, size, use, status and letter define the approval scope.

01

Product-specific

One GA number may contain several models, sizes or configurations.

02

Status can change

A record may be updated when approval expires, is suspended, reinstated or removed.

03

Official record prevails

JACO provides the search interface; WSD remains the authoritative source.

Frequently asked questions

GA water-fitting search questions

What is the difference between WELS and a “water paper” or GA record?

A “water paper” usually means a WSD General Acceptance (GA) record. It pre-approves a specific plumbing product against relevant statutory material standards and carries an acceptance status and expiry date. WELS indicates water consumption and water-efficiency grade so buyers can compare water-saving performance. They serve different purposes and do not replace each other; check the GA record and WELS registration separately when relevant.

Does one GA number approve every tap sold under the same brand?

No. General Acceptance normally applies to specified models, sizes, fitting classifications and uses. Check every exact product record, even within one brand or range.

Why does the same GA number appear in several results?

A GA letter can cover several models, diameters, sizes or configurations. This finder keeps those rows separate to avoid merging unlike specifications.

What is the difference between expired, suspended and removed?

Expired means the acceptance period has ended; suspended means acceptance is temporarily paused; removed means it has been withdrawn. Review the official details before use.

Can a JACO result be used directly for a formal plumbing submission?

This tool supports discovery and specification checks. It does not replace the WSD directory, the official GA letter or professional judgement. Verify the official record before submission.

Need help matching a model to a project specification?

Share the GA number, complete model, size and intended use, and JACO can help structure the procurement specification.

Contact JACO