JACO

Hong Kong WSD General Acceptance

Find the right fitting. Verify it at a glance.

Search Hong Kong WSD General Acceptance records by GA number, brand, complete model or product type, then verify the image, size, approval period and latest status.

Sourced directly from the official WSD GA directory and refreshed continuously

02 / RESULTS

Search results

18,474 matching recordsEach row represents an exact model/size; one GA letter may cover multiple product rows.Data retrieved: 5 Nov 2026, 11:54

Winkler

WK-PR822

Single lever basin mixer
Size
3/8 inch
Water-supply system
Fresh Water
GA numberC20200825
Expired
WSD #1013842
Origin
Chinese Mainland
Approval date
18 Sept 2020
Expiry date
1 Jul 2025
Quality-assurance evidence
Quality management system

Winkler

WK-PR812

Single lever basin mixer
Size
3/8 inch
Water-supply system
Fresh Water
GA numberC20200824
Expired
WSD #1013841
Origin
Chinese Mainland
Approval date
18 Sept 2020
Expiry date
1 Jul 2025
Quality-assurance evidence
Quality management system

Neoperl

44.3151.000

Flow controller
Water-supply system
Fresh Water
GA numberC20200823
Expired
WSD #1013840
Origin
Germany
Approval date
18 Sept 2020
Expiry date
3 Aug 2025
Quality-assurance evidence
Quality management system
Winkler WK-44 · GA number C20200822

Winkler

WK-44

Wall mounted shower mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20200822
Expired
WSD #1002033
Origin
Chinese Mainland
Approval date
17 Sept 2020
Expiry date
9 Jul 2025
Quality-assurance evidence
Quality management system
Winkler WK-15 · GA number C20200821

Winkler

WK-15

Wall mounted bath and shower mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20200821
Expired
WSD #1013839
Origin
Chinese Mainland
Approval date
17 Sept 2020
Expiry date
9 Jul 2025
Quality-assurance evidence
Quality management system
Winkler WK-43 · GA number C20200820

Winkler

WK-43

Wall mounted sink mixer
Size
1/2 inch
Water-supply system
Fresh Water
GA numberC20200820
Expired
WSD #1001984
Origin
Chinese Mainland
Approval date
17 Sept 2020
Expiry date
9 Jul 2025
Surveillance status
Pass · 29 Feb 2024
Quality-assurance evidence
Quality management system
RENÉ A1014 · GA number C20200819F

RENÉ

A1014

Plastic float operated valve
Size
1/2 inch
Water-supply system
Flushing Water
GA numberC20200819F
Expired
WSD #1013838
Origin
Chinese Mainland
Approval date
17 Sept 2020
Expiry date
3 Aug 2025
Quality-assurance evidence
Quality management system

Franke

PT231C

Single lever kitchen mixer
Size
3/8 inch
Water-supply system
Fresh Water
GA numberC20200818
ExpiredWELS
WSD #1013837
Origin
Italy
Approval date
17 Sept 2020
Expiry date
31 Oct 2022
Quality-assurance evidence
Quality management system
Water-efficiency label
TM 19-0024 · grade 1 · nominal flow 3.6

Winkler

WK-SA802

Single lever basin mixer
Size
3/8 inch
Water-supply system
Fresh Water
GA numberC20200815
Expired
WSD #1013836
Origin
Chinese Mainland
Approval date
17 Sept 2020
Expiry date
14 Jul 2025
Quality-assurance evidence
Quality management system
Kims C-5088 range · GA number C20200814F

Kims

C-5088 range

Plastic single flush valve
Size
2 inch
Water-supply system
Flushing Water
GA numberC20200814F
Expired
WSD #1013835
Origin
Chinese Mainland
Approval date
17 Sept 2020
Expiry date
9 Jul 2025
Quality-assurance evidence
Quality management system

Roca

A5253863607

Flow controller
Water-supply system
Fresh Water
GA numberC20200813
Expired
WSD #1013834
Origin
Germany
Approval date
17 Sept 2020
Expiry date
3 Jul 2025
Quality-assurance evidence
Quality management system

Winkler

WK-MI802

Single lever basin mixer
Size
3/8 inch
Water-supply system
Fresh Water
GA numberC20200812
Expired
WSD #1013833
Origin
Chinese Mainland
Approval date
15 Sept 2020
Expiry date
1 Jul 2025
Quality-assurance evidence
Quality management system

A quick pre-procurement check

Understand a WSD GA record in three steps

Confirm the product identity first, then its approval scope. A matching brand or appearance alone is not enough.
  1. 01

    Match the GA number and model

    Check the GA number, brand and complete model against the product. Related models in the same range are not automatically covered.

  2. 02

    Check size and intended use

    One GA letter can cover several sizes or configurations. Match the water-supply system, size and fitting classification to the work.

  3. 03

    Review expiry and surveillance

    Confirm that approval is not expired, suspended or removed, and re-open the official record before a formal submission or inspection.

What is General Acceptance?

A GA record is a key reference when checking plumbing-product compliance

Pipes and fittings used in Hong Kong inside-service and fire-service installations must meet Water Authority requirements. Accepted products receive a General Acceptance record; its official model, size, use, status and letter define the approval scope.

01

Product-specific

One GA number may contain several models, sizes or configurations.

02

Status can change

A record may be updated when approval expires, is suspended, reinstated or removed.

03

Official record prevails

JACO provides the search interface; WSD remains the authoritative source.

Frequently asked questions

GA water-fitting search questions

What is the difference between WELS and a “water paper” or GA record?

A “water paper” usually means a WSD General Acceptance (GA) record. It pre-approves a specific plumbing product against relevant statutory material standards and carries an acceptance status and expiry date. WELS indicates water consumption and water-efficiency grade so buyers can compare water-saving performance. They serve different purposes and do not replace each other; check the GA record and WELS registration separately when relevant.

Does one GA number approve every tap sold under the same brand?

No. General Acceptance normally applies to specified models, sizes, fitting classifications and uses. Check every exact product record, even within one brand or range.

Why does the same GA number appear in several results?

A GA letter can cover several models, diameters, sizes or configurations. This finder keeps those rows separate to avoid merging unlike specifications.

What is the difference between expired, suspended and removed?

Expired means the acceptance period has ended; suspended means acceptance is temporarily paused; removed means it has been withdrawn. Review the official details before use.

Can a JACO result be used directly for a formal plumbing submission?

This tool supports discovery and specification checks. It does not replace the WSD directory, the official GA letter or professional judgement. Verify the official record before submission.

Need help matching a model to a project specification?

Share the GA number, complete model, size and intended use, and JACO can help structure the procurement specification.

Contact JACO